BS EN 1276 : 1997
CHEMICAL DISINFECTANTS AND ANTISEPTICS – QUANTITATIVE
SUSPENSION TEST
TESTING WAS CONDUCTED AS DESCRIBED
IN BS EN 1276
| Products under test |
D-STROY/Activ8 |
23/68771 |
| Test Organism |
Inoculum level cfu/ml |
Test suspension cfu/ml |
| Aspergillus niger |
1.2 x  |
1.28 x  |
| Candida albicans |
1.3 x  |
1.30 x  |
RESULTS
Recovery of Test organisms after specific contact with product
under test.
Temperature 20 + 1.0°C
23/68771
RECOVERY CFU/ML OF TEST SUSPENSION PER CONTACT TIME STATED
| Product contact time |
1.0 minutes |
5.0 minutes |
15.0 minutes |
| Test Organism |
|
|
|
| Aspergillus niger |
100 |
< 10 |
< 10 |
| Candida albicans |
20 |
< 10 |
< 10 |
RESULTS
DISPLAYED ARE THE MEANS OF DUPLICATE ANALYSES
23/68771
PERCENTAGE REDUCTION PER CONTACT TIME STATED
| Product contact time |
1.0 minutes |
5.0 minutes |
15.0 minutes |
| Test Organism |
|
|
|
| Aspergillus niger |
>99.999 |
>99.999 |
>99.999 |
| Candida albicans |
>99.999
|
>99.999 |
>99.999 |
PERFORMANCE
CRITERIA
D-Stroy/Activ8 complies with the requirements of the BS EN 1276: 1997
for reduction of microbial loading per time interval. With a >
Log 5 reduction in counts at all of the three time intervals selected.
Product Passes the Suspension Test
|